American Fibertek SM24p-PoE Manuel d'instructions Page 71

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 125
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 70
User Manual
Rev.A1
1-Mar-11
63
DC Disconnect Port Off:
Port is turned off due to the DC Disconnect function.
Overload Port Off:
The switch will stop supplying the power to the port due to the power
required by the PD that is linked to the port on the switch excesses the
Class setting of the PD.
Short Circuit Port Off:
The switch will stop supplying the power to the port if it detects that the
PD linked to the port is short circuit.
Over Temp. Protection:
The port of the switch will be disabled due to fast transient rise in
temperature to 240
o
C or slow rise in temperature to 200
o
C.
Power Management Port Off:
Due to total power required by all PDs linked to the switch excesses the
power limit, so the switch stops supplying the power to this port after
referring to the information of the priority.
Vue de la page 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 124 125

Commentaires sur ces manuels

Pas de commentaire